Leading manufacturer of cable trays, support systems, and accessories

Hazardous Area Cable Routing (ATEX / IECEx)

Table of Contents

Engineered cable routing and support systems for hazardousarea installations in oil & gas, petrochemical, chemical processing, LNG, offshore, and industrial facilities where explosive gas or combustible dust atmospheres may be present.

Designed to support safe and compliant routing of power, instrumentation, communication, and emergency system cabling across Zone 0, Zone 1, Zone 2, Zone 21, and Zone 22 classified environments under ATEX and IECEx requirements.

Scenario Challenge

Ignition Risk from Improper Grounding and Bonding

In hazardous environments, discontinuous grounding paths, loose metallic connections, or inadequate bonding between tray sections can create potential ignition sources during fault conditions or static discharge events.

Segregation of Critical Safety and Instrumentation Systems

Emergency shutdown (ESD), intrinsically safe instrumentation, fiber optic communication, and MV power systems often share congested routing corridors. Improper segregation increases EMC interference risks and compromises safety system integrity.

Corrosion and Environmental Degradation in Classified Areas

Hazardousarea installations are frequently exposed to hydrocarbons, chemical vapors, offshore salt spray, and aggressive washdown conditions that can degrade support systems and grounding continuity over time.

Complex Compliance Across International Standards

EPC contractors and operators must ensure cable support systems comply with ATEX directives, IECEx requirements, IEC 60079 standards, grounding continuity requirements, and projectspecific hazardousarea specifications simultaneously.

Solution Overview

Typical Hazardous Area Cable Routing Layout

Safe Area Substation / MCC
            ↓
Hazardous Area Boundary
            ↓
Main Cable Rack Corridor
            ↓
Zone 2 Process Area
            ↓
Zone 1 Equipment Area
            ↓
Field Junction Boxes / Instruments
Hazardous Area Routing Philosophy
Safe Area → Hazardous Area Transition

Power and control cables transition from substations or MCC rooms into classified process areas through dedicated tray systems with grounding continuity and fire barrier integration.

Main Trunk Routing

Primary cable ladders distribute MV/LV power, instrumentation, and communication systems along process pipe racks and utility corridors while maintaining required cable segregation distances.

ZoneBased Segregation Strategy

Different hazardous classifications require separate routing logic for:

Intrinsically safe instrumentation

Emergency shutdown systems

MV power cables

Fiber optic communication

Fire & gas systems

Local Equipment Distribution

Final cable drops to field instruments, motors, analyzers, and junction boxes are supported using corrosionresistant localized support assemblies.

AreaBased Engineering Selection

1. Hazardous Area Boundary Transition

Typical Requirements

  • Grounding continuity
  • Fire barrier integration
  • Expansion sealing interfaces

Recommended Systems

  • Heavy Duty Ladder Tray
  • Bonding Jumper Assemblies
  • Firestop Support Frames
  • Engineering Selection Logic
  • Hazardousarea boundaries require electrically continuous support systems capable of maintaining bonding integrity during fault conditions while supporting firerated penetrations between safe and classified zones.

Key Parameters

  • Lowresistance bonding continuity
  • Firestop compatibility
  • Faultcurrent resistance

2. Zone 2 Process Utility Corridors

Typical Requirements

  • Multiservice routing
  • Corrosion resistance
  • Accessible maintenance routing

Recommended Systems

  • HDG Ladder Tray
  • Aluminum Cable Tray
  • MultiTier Support Systems
  • Engineering Selection Logic
  • Zone 2 areas typically prioritize maintainability and longspan routing efficiency while maintaining corrosion protection and EMC segregation.

Key Parameters

  • Segregated routing layers
  • Span distances up to 6 m
  • C4/C5 corrosion protection

3. Zone 1 Process Equipment Areas

Typical Requirements

  • Maximum grounding reliability
  • Chemical resistance
  • Dense equipment routing

Recommended Systems

  • SS316L Ladder Tray
  • FRP Cable Ladder
  • Stainless Steel Fastening Systems
  • Engineering Selection Logic
  • Zone 1 installations require enhanced corrosion protection and longterm grounding continuity due to continuous exposure to explosive atmospheres and aggressive process chemicals.

Key Parameters

  • IEC 60079 compatibility
  • C5M / CX corrosion class
  • High bonding reliability

4. Intrinsically Safe Instrumentation Routing

Typical Requirements

  • EMC protection
  • Dedicated cable separation
  • Flexible field modifications

Recommended Systems

  • Wire Mesh Tray
  • Dedicated Instrumentation Tray
  • Modular Strut Supports
  • Engineering Selection Logic
  • Instrumentation systems require isolated routing paths to reduce electromagnetic interference and simplify future system modifications during plant upgrades.

Key Parameters

  • IS cable segregation
  • Lightweight routing
  • Fast modification capability

5. Offshore Hazardous Areas

Typical Requirements

  • Marine corrosion resistance
  • Structural vibration resistance
  • Lightweight support systems

Recommended Systems

  • SS316L Cable Ladder
  • MarineGrade Aluminum Tray
  • OffshoreRated Support Hardware
  • Engineering Selection Logic
  • Offshore hazardous environments combine explosive atmosphere requirements with severe marine corrosion exposure and dynamic platform movement.

Key Parameters

  • EN ISO 12944 CX protection
  • Offshore vibration resistance
  • Reduced structural dead load
  • Hazardous Area Cable Segregation Strategy
System Type Recommended Routing Method Typical Separation Requirement
MV Power Cables Independent ladder level Maximum EMC separation
LV Power Distribution Shared power corridor Physical separation from IS systems
Intrinsically Safe Instrumentation Dedicated tray routing Isolated from power systems
Fiber Optic Communication Upper tray level Low EMI exposure
Fire & Gas Systems Fire-rated independent routing Emergency survivability

Grounding & Bonding Continuity Design

Integrated Bonding Strategy

All metallic tray sections, couplers, supports, and expansion joints are designed to maintain continuous grounding paths across the entire hazardousarea routing network.

Expansion Joint Bonding

Dedicated bonding jumpers maintain electrical continuity across thermal expansion splice assemblies.

Fault Current Considerations

Support systems are designed to withstand electromechanical forces generated during shortcircuit conditions.

CorrosionProtected Connections

Stainless steel fasteners and corrosionresistant bonding hardware reduce longterm grounding degradation risks.

Corrosion Protection Strategy

Hot Dip Galvanized Systems

Suitable for general outdoor Zone 2 applications requiring economical corrosion resistance.

SS316L Stainless Steel Systems

Recommended for aggressive hydrocarbon processing areas and offshore classified environments.

Duplex Coating Systems

Provide extended maintenance intervals in coastal and chemicalprocessing hazardous areas.

FRP NonMetallic Systems

Ideal for highly corrosive environments where conductive metallic corrosion is a concern.

Related Products

Product Type Recommended Hazardous Area Application Why Recommended Certifications
Heavy Duty Ladder Tray Main hazardous-area power routing Maintains grounding continuity under high loads IEC 61537
SS316L Ladder Tray Zone 1 process areas Superior corrosion & bonding reliability IEC / ASTM
FRP Cable Ladder Chemical exposure zones Corrosion-free non-metallic solution NEMA FG 1
Aluminum Cable Tray Long-span utility corridors Lightweight & corrosion resistant IEC 61537
Wire Mesh Tray Instrumentation systems Flexible IS cable routing IEC / CE
Cable Cleat Systems MV cable restraint Fault-current resistance IEC 61914
Bonding Jumpers Expansion joint continuity Maintains grounding integrity IEC
Fire-Rated Supports Emergency systems Supports circuit survivability IEC

Technical Certifications

ATEX Directive 2014/34/EU

Applicable to equipment and installations operating in explosive atmospheres within European hazardousarea projects.

Why It Matters

Supports regulatory acceptance for projects within EU jurisdictions and EPC specifications requiring ATEX compliance.

IECEx Certification System

International certification framework for equipment and systems installed in explosive atmospheres.

Why It Matters

Simplifies international project approval across multiregion oil & gas and industrial facilities.

IEC 60079 Series

Defines installation, protection, inspection, and maintenance requirements for hazardousarea electrical systems.

Why It Matters

Critical for ensuring safe cable routing design within explosive gas and dust atmospheres.

IEC 61537

Specifies load testing, grounding continuity, and mechanical performance requirements for cable tray systems.

Why It Matters

Ensures cable support systems maintain structural and electrical integrity during operation.

IEC 61914

Defines shortcircuit performance requirements for cable cleat systems.

Why It Matters

Supports restraint of MV cables during faultcurrent events.

EN ISO 12944

Defines corrosion protection classifications for industrial and offshore environments.

Why It Matters

Helps select suitable coating systems for longterm hazardousarea durability.

Project Cases

LNG Export Terminal — Middle East

Project Scope

Hazardousarea cable routing systems across LNG process trains, compressor units, and utility corridors.

Installed System

  • SS316L cable ladders
  • Firerated emergency routing systems
  • Bonding continuity assemblies
  • Project Results
  • More than 26 km of hazardousarea cable routing installed
  • Passed ATEX and IECEx project inspections
  • Reduced longterm corrosion maintenance requirements

Offshore Petrochemical Platform — Southeast Asia

Project Scope

Cable support infrastructure for offshore hazardousarea instrumentation and power distribution systems.

Installed System

  • Marinegrade aluminum tray systems
  • Offshorerated bonding hardware
  • MV cable cleat systems
  • Project Results
  • Improved offshore installation efficiency
  • Reduced structural dead load on topside modules
  • Successfully completed hazardousarea commissioning approval

Download

Technical Resources

  • Hazardous Area Cable Routing Design Guide
  • ATEX / IECEx Installation Reference
  • Grounding & Bonding Continuity Manual
  • Hazardous Area Cable Segregation Guide
  • BIM Models for Classified Area Installations
  • IEC 60079 & IEC 61537 Compliance Documentation

Next Step

Consult Hazardous Area Cable Routing Engineering

Discuss ATEX / IECEx routing requirements, grounding continuity strategies, and hazardousarea segregation design with our engineering team.

Request Hazardous Area Material Samples

Evaluate SS316L, FRP, aluminum, and duplexcoated systems for classifiedarea applications.

Download Hazardous Area Technical Manual

Access hazardousarea installation practices, bonding requirements, tray loading data, and project reference configurations.

Welcome To Share This Page:
Product Categories
Get A Free Quote
Contact Form

This information helps us route your inquiry to the appropriate engineering support team.

Scroll to Top
Get A Free Quote Now !
Contact Form

This information helps us route your inquiry to the appropriate engineering support team.